BEPU 8018 is a two-component-free-free room temperature or a heat-curable polyurethane gel for two-component sealing and filling. The raw material does not contain heavy metals, green environmental protection, wide process, high finished physical properties, and good binding properties. The room temperature and heating curing can be deeply cured, and the two groups have a good fluidity after mixing, the hardness is extremely low, the flexibility is excellent, and the low temperature resistance is excellent. It is used in communication equipment, transformers, control power, ignition Pouring and potting of controllers, electronic sensors, etc.
Test items | Unit and condition | Test standard | BEPU 8018#2 A / B | |
Appearance | A | Visual | Visual | Yellow transparent fluid |
B | Visual | Yellow transparent fluid | ||
Viscosity |
A |
25℃ mPa·s |
GB/T 10247-2008 | 400±200 |
B | GB/T 10247-2008 | 400±200 | ||
A+B | GB/T 10247-2008 | 400±200 | ||
Density |
A |
25℃ g/cm3 |
GB/T 15223-1994 | 1.00±0.05 |
B | GB/T 15223-1994 | 0.95±0.05 | ||
A+B | GB/T 15223-1994 | 1.00±0.05 | ||
Operating time | 25℃, minutes, 150g,
Viscosity up to 100,000cps |
GB/T 10247-2008 |
40~60 |
|
Gel time | 25℃hrs | GB/T 10247-2008 | 1~2 | |
Mixed ratio | Weight ratio | —- | A :B=100 :100 | |
Curing condition | ℃/h | —- | 25℃/ 24 h or 70℃/2h |
Characteristics after curing
Items | Unit and condition | Test standard | 8018(2#) |
Color | Visual | Visual | Yellow transparent |
Hardness | Shore 00 | GB/T 4985—2010 | 30±10 |
Water absorption rate | 24hrs, 25℃,% | GB/T 8810-2005 | <0.02 |
Thermal Conductivity | W/m.K | GB/T10297-1998 | 0.10 |
Glass transition temperature Tg | ℃ | GBT 11998-1989 | -70 |
Volume resistivity | 25℃,Ω·cm | GB/T 1692-92 | 2.5*1014 |
Dielectric strength | 25℃,kV/mm | GB/T 1695-2005 | >25 |
Dielectric constant | 50Hz,25℃ | GB/T 1693-2007 | 2.7 |
Dielectric loss | 50Hz,25℃ | GB/T 1693-2007 | 0.002 |
Linear thermal expansion | μm/(m,℃) | GBT 20673-2006 | 230 |
Application temperature | ℃ | GBT 20028-2005 | -80~120 |
* Note: The above performance data is a typical data of the product at a humidity of 70% and a temperature of 25 ° C. It is not possible to fully guarantee all the data that can be achieved in a particular environment. Please use the measured data when you please use it.
It is used in communication equipment, transformers, control power, ignition Pouring and potting of controllers, electronic sensors, etc.
How to use: